Linen Chute

Linen Chute

Garbage_Chute

Key Features

The Linen Chute is designed for efficient linen disposal in hotels, hospitals, and high-rise buildings, ensuring cleanliness and safety.

VENTILLATION

The purpose of a vent is to dissipate odors, as well as to dissipate hot gases in the event of a fire within the chute. NFPA codes require a full diameter vent penetrating and extending 3 above the roof 

REGULAR CHUTE 

The standard chute extends form the garbage collection room to the top floor where the highest intake is locted. The tubes are continuously TIG welded ensuring a watertight system without any bolts rivets or other projections inside the chute.

CHUTE INTAKE
Chute intakes are designed to securely hold hopper doors, The intake sections are continuously welded internally rectified and extemally sealed with mastic to ensure they are free form abstructions

COMPACTOR

solid waste in your building has been brought down to street level with a dedicated wastte chute and the collected to compactor.

CHUTE DOORS

The doors are crafted from a solid, mono block stainless steel surface and feature specially designed gas pistons for easier and safer operation. Electromagnetic interlocking with LED indicator lamps ensures that only one user can operate the chute at a time, and all doors automatically lock during maintenance.

ACCESS DOOR

The Access Door is located above the top intake of the chute, allows access to the valves that operate the flushing spray head and/or sanitizing unit.

OFFSET CHUTE

He offset design allows for flexibility in routing the chute around structural elements, ensuring optimal space utilization. Built with robust materials and precise engineering, these chutes offer reliable performance and seamless integration with building layouts, enhancing both functionality and safety.

DISCHARGE DOOR

Installed on the bottom of the chute, and held open by a 165°F (74°C) fusible link (UL listed). It will cut off and close the chute once fire happened in the garbage collection room and the link are melted when the ambient temperature of a fire reaches 165 °F.

SUPPORT BRACKET

Chute support frames are used for supporting the system on each floor. Chute support frames are fixed around the chute and bolted to the structure and wall. The interior of the rings is covered with 3mm anti vibration rubber pad as a sound isolator and protects the chutes from corrosion.

CONTROL PANEL

The control panel, situated in the garbage collection room, is equipped with essential switches, relays, and indicator lights for operating chute accessories such as automatic sanitizing systems, exhaust fans, brushing units, and interlocking doors. Additionally, the control panel is integrated with the fire and smoke alarm system to automatically lock the chute in case of a fire.

Linen Chute

High-Performance Linen

Durable and resistant to corrosion, ensuring long-lasting performance in demanding environments.

Smart Linen Transfer Solution

Equipped with safety-rated doors to prevent the spread of fire and enhance overall building safety.

Effortless Linen System

Effortless Linen System Adaptable to fit various building heights and layouts for maximum flexibility.

Linen Chute

The Linen Chute is designed for the efficient and safe disposal of soiled linens in hospitals, hotels, and large facilities, offering a clean and organized laundry management solution.